At After Market Industrials, you can find the items listed with the NSN 5930-00-790-3937. We have an array of related part numbers including L6021CS2X0X1, T678A1015, T678A-1015, and many others in stock and ready for purchase at any time. When you need superior quality NSN parts and components, contact the experts at After Market Industrials. Browse our various NSN 5930-00-790-3937 part lists at your leisure and take note of any items of interest. When you are ready, we invite you to take advantage of our Instant RFQ service, which will allow you to request competitive quotes for any featured products. Within 15 minutes of receiving and reviewing a completed Request for Quote (RFQ) form, a dedicated representative will reach out with a customized solution that keeps your unique parameters in mind. For additional questions, call or email us directly; we are available around the clock!
Item Name | Switch Thermostatic |
Federal Supply Group (FSG) | 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5930 Switches |
NIIN | 00-790-3937 (007903937) |
NCB Code | USA (00) |
Part No | Manufacturer | Item Name | QTY | RFQ |
---|---|---|---|---|
L6021CS2X0X1 | honeywell international inc | switch thermostatic | Avl | RFQ |
T678A1015 | honeywell international inc | switch thermostatic | Avl | RFQ |
T678A-1015 | dow corning corporation | switch thermostatic | Avl | RFQ |
T678A1015 | honeywell inc | switch thermostatic | Avl | RFQ |
L6021CS2X0X1 | honeywell inc | switch thermostatic | Avl | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | III OVERALL LENGTH | 2.000 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 5.625 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 2.625 INCHES NOMINAL |
AEVT | CAPILLARY TUBE LENGTH | 240.0 INCHES NOMINAL |
AKBY | TEMP SENSING ELEMENT TYPE | CAPILLARY TUBE |
AWTN | OPERATING TEMP RATING | 125.0 DEG FAHRENHEIT MAXIMUM |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
CTHF | CONTACT LOAD CURRENT RATING | 5.1 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
CTYC | CONTACT ADJUSTABILITY | ACTUATION POINT ADJUSTABLE |
CTYM | CONTACT ADJUSTMENT RANGE | +0.00/+100.00 ACTUATION POINT DEGREES FAHRENHEIT |
CTYS | CONTACT ADJUSTMENT TYPE | EXTERNAL ACTUATION POINT KNOB WITH SCALE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 120.0 AC AT SEA LEVEL FIRST VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 240.0 AC AT SEA LEVEL SECOND VOLTAGE |
MEDA | MEDIA FOR WHICH DESIGNED | LIQUID OR GAS |
STYL | III STYLE DESIGNATOR | RECTANGULAR |
CTHF | CONTACT LOAD CURRENT RATING | 8.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
5905-00-000-0136 (5905000000136) | 5905-00-001-2573 (5905000012573) | 5905-00-001-2813 (5905000012813) | 5905-00-001-2834 (5905000012834) |
5905-00-001-2852 (5905000012852) | 5905-00-001-2882 (5905000012882) | 5905-00-001-2890 (5905000012890) | 5905-00-001-2920 (5905000012920) |
5905-00-001-2934 (5905000012934) | 5905-00-001-2951 (5905000012951) | 5905-00-001-2952 (5905000012952) | 5905-00-001-2954 (5905000012954) |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
We Hope that You Will Visit Us Again the Next Time You Need NSN Parts and Make Us Your Strategic Purchasing Partner.
Request for Quote