At After Market Industrials, you can find the items listed with the NSN 5990-00-099-0699. We have an array of related part numbers including 26V-08CT4C, MS20708-79D002, M20708 79-002, MIL-S-20708 79, SAE-AS20708 79, and many others in stock and ready for purchase at any time. When you need superior quality NSN parts and components, contact the experts at After Market Industrials. Browse our various NSN 5990-00-099-0699 part lists at your leisure and take note of any items of interest. When you are ready, we invite you to take advantage of our Instant RFQ service, which will allow you to request competitive quotes for any featured products. Within 15 minutes of receiving and reviewing a completed Request for Quote (RFQ) form, a dedicated representative will reach out with a customized solution that keeps your unique parameters in mind. For additional questions, call or email us directly; we are available around the clock!
Item Name | Synchro Control Tra |
Federal Supply Group (FSG) | 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5990 Synchros and Resolvers |
NIIN | 00-099-0699 (000990699) |
NCB Code | USA (00) |
MRC | Criteria | Characteristic |
---|---|---|
AAFZ | BODY MATERIAL | STEEL, STAINLESS |
AAQL | BODY STYLE | STANDARD ROUND A |
AAVL | PILOT DIAMETER | 0.4995 INCHES MINIMUM AND 0.5000 INCHES MAXIMUM |
ABHP | OVERALL LENGTH | 1.6150 INCHES NOMINAL |
ABKK | FLANGE DIAMETER | 0.7450 INCHES MINIMUM AND 0.7500 INCHES MAXIMUM |
ABKU | FLANGE THICKNESS | 0.0620 INCHES NOMINAL |
ABPA | UNDERCUT DIAMETER | 0.6870 INCHES NOMINAL |
ABPC | UNDERCUT WIDTH | 0.0620 INCHES NOMINAL |
ABWV | SHAFT DIAMETER | 0.0895 INCHES MINIMUM SINGLE SHAFT AND 0.0900 INCHES MAXIMUM SINGLE SHAFT |
ABXF | SHAFT LENGTH | 0.5500 INCHES NOMINAL SINGLE SHAFT |
AFJN | III FRAGILITY FACTOR | MODERATELY RUGGED |
AHCG | MAXIMUM TEMP RISE | 10.0 DEG CELSIUS |
AJSL | BODY SIZE | 8 |
AJSN | STATOR INPUT VOLTAGE RATING IN VOLTS | 10.2 NOMINAL |
AJSP | STATOR INPUT CURRENT RATING | 23.0 MILLIAMPERES NOMINAL |
AJSQ | STATOR INPUT ELECTRICAL POWER RATING | 0.053 WATTS MAXIMUM |
AJSS | FREQUENCY IN HERTZ | 400.0 NOMINAL |
AJTJ | ZSO IMPEDANCE MAGNITUDE IN OHMS | 444.00 MINIMUM AND 70.00 MAXIMUM |
AJTK | ZSO IMPEDANCE ANGLE IN DEG | 76.00 MINIMUM AND 81.00 MAXIMUM |
AJTL | ZRS IMPEDANCE MAGNITUDE IN OHMS | 830.00 MINIMUM AND 940.00 MAXIMUM |
AJTM | ZRS IMPEDANCE ANGLE IN DEG | 16.00 MINIMUM AND 20.00 MAXIMUM |
AJVF | PHASE SHIFT ANGLE IN DEG | 8.000 INPUT TO OUTPUT NOMINAL |
AJVG | MAXIMUM FUNDAMENTAL NULL VOLTAGE IN MILLIVOLTS PER VOLT | 25.00 OUTPUT |
AJVH | MAXIMUM TOTAL NULL VOLTAGE OUTPUT IN MILLIVOLTS PER VOLT | 30.00 |
AJVL | ELECTRICAL ERROR ANGULAR RANGE IN MINUTES | -7.0 TO 7.0 |
AJVV | TORQUE GRADIENT PER ANGULAR DEG | 0.040 INCH-OUNCES MAXIMUM |
AJWQ | PILOT LENGTH | 0.0620 INCHES NOMINAL |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 1.2400 INCHES NOMINAL |
CQTM | TERMINAL LOCATION | REAR |
CQZS | SHAFT SLOT DEPTH | 0.0250 INCHES NOMINAL SINGLE SHAFT |
CRHN | SHAFT SLOT WIDTH | 0.0200 INCHES NOMINAL SINGLE SHAFT |
CRSJ | SHAFT TYPE | ROUND, SLOTTED SINGLE SHAFT |
CSJY | TRANSFORMATION RATIO | 2.203 ROTOR TO STATOR NOMINAL |
TEST | TEST DATA DOCUMENT | 81349-MIL-S-20708 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTI |
TTQY | TERMINAL TYPE AND QUANTITY | 5 WIRE LEAD |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-S-20708/79 GOVERNMENT SPECIFICATION |
5905-00-000-0136 (5905000000136) | 5905-00-001-2573 (5905000012573) | 5905-00-001-2813 (5905000012813) | 5905-00-001-2834 (5905000012834) |
5905-00-001-2852 (5905000012852) | 5905-00-001-2882 (5905000012882) | 5905-00-001-2890 (5905000012890) | 5905-00-001-2920 (5905000012920) |
5905-00-001-2934 (5905000012934) | 5905-00-001-2951 (5905000012951) | 5905-00-001-2952 (5905000012952) | 5905-00-001-2954 (5905000012954) |