Get a Quote for Part JD2-A3A16-DU having NSN 5925-01-174-7493 Manufactured by Reliance Comm Tec Corp

Mfg Part Number: JD2-A3A16-DU Alternate P/N: JD2A3A16DU NSN : 5925-01-174-7493
NIIN : 011747493 CAGE Code : 74006 Manufacturer: Reliance Comm Tec Corp
Item Name : Circuit Breaker FSC : 5925 Circuit Breakers

Thank you for your interest in the Circuit Breaker components we have available on After Market Industrials. This particular Reliance Comm Tec Corp item is listed alongside the NSN 5925-01-174-7493 and part number JD2-A3A16-DU for your reference. With current availability for this product, we encourage you to utilize our Instant RFQ service in order to receive a competitive quote within 15 minutes or less of you submitting a Request For Quote form. At After Market Industrials, we are backed by our rapid lead times and cost savings, allowing all of our customers to meet their operational deadlines. More than that, we thoroughly vet our products prior to shipping.

PRODUCT DETAILS “*” Required Fields Are Compulsory

CONTACT INFORMATION

  • I consent to receive email communications from ASAP Semiconductor and can unsubscribe at any time.
  • ASAP Semiconductor is a wholly independent aftermarket parts distributor.
  • This website is intended for quotations based on part numbers only. Please DO NOT submit drawings, technical data, or other specifications through this portal.

Note : We Will Not Share Your Information To Any Third Parties.

  • Upload RFQ SHEET
  • If you have more than one item, upload your spreadsheet here

Take time in looking through our expansive catalogs and you will find that the NSN 5925-01-174-7493 can be found listed under CAGE Code 74006. We also have numerous other NSN parts, all of which are sourced from leading global manufacturers like Reliance Comm Tec Corp. To begin the purchasing process, fill out and submit a quote request that includes all of your part requirements and see why customers continually rely on us as their go-to sourcing solution. For additional questions, call or email us directly; we are on standby for our customers.

NSN Information for Part Number JD2-A3A16-DU with NSN 5925-01-174-7493, 5925011747493

NSNFSCNIINCLSHazmatDEMILCancelled NSN
5925-01-174-7493

Item Description:

Circuit Breaker

59250117474930P
CIICHCCESDPMICCriticalityENAC
U A
Part NumberISCRNVCRNCCHCCMSDSSADC
Jd2-A3a16-Du595

Characteristics Data of NSN 5925-01-174-7493, 5925011747493

MRCCriteriaCharacteristic
AAQLBODY STYLEMULTIPOLE-MULTIPLE ACTUATOR TYPE
ABXDBUSHING LENGTH0.625 INCHES NOMINAL
ADAQBODY LENGTH2.000 INCHES NOMINAL
ADATBODY WIDTH2.250 INCHES NOMINAL
ADTVCASE MATERIALPLASTIC
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH1.560 INCHES NOMINAL
AEBQCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH0.750 INCHES NOMINAL
AFJNFRAGILITY FACTORMODERATELY RUGGED
AJWXMOUNTING SURFACE TO TERMINAL END DISTANCE1.843 INCHES NOMINAL
AKPXPOLE QUANTITY2
AXHRMOUNTING FACILITY TYPE AND QUANTITY4 THREADED HOLE
BBRGSTORAGE TYPEGENERAL PURPOSE WAREHOUSE
BBRJSPECIAL HANDLING FEATUREMAGNETIC
CMLPTHREAD QUANTITY PER INCH32
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE0.05 MILLIAMPERES AC SECOND LOCATION
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE6.0 AMPERES AC FIRST LOCATION
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS240.0 AC ALL LOCATIONS
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS5000.0 AC ALL LOCATIONS
CPRHCIRCUIT PROTECTION TYPEOVERCURRENT ALL LOCATIONS
CPRJTRIP RELEASE METHODMAGNETIC-HYDRAULIC ALL LOCATIONS
CPRLTRIP RELEASE CHARACTERISTICTIME DELAY ALL LOCATIONS
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT125.0 ALL LOCATIONS
CPRQRESET METHODMANUAL
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
CPRTMANUAL ACTUATOR TYPE AND QUANTITY2 PUSH BUTTON
CPRWACTUATOR FUNCTIONTRIP-RESET
CPRXACTUATOR POSITION DESIGNATIONAT EACH POLE
CPRYEXTERNAL ACTUATOR LINKAGE ARRANGEMENTONE AND TWO LINKED
CPSMINTERNAL TRIP RELEASE CONFIGURATIONRELAY TRIP SECOND LOCATION
CPSMINTERNAL TRIP RELEASE CONFIGURATIONSERIES TRIP FIRST LOCATION
CQJXNOMINAL THREAD SIZE0.138 INCHES
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT0.300 MINIMUM AT 200 PCT ALL LOCATIONS AND 5.000 MAXIMUM AT 200 PCT ALL LOCATIONS
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDFUNGUS RESISTANT AND HUMIDITY RESISTANT AND MOISTURE RESISTANT
FREQFREQUENCY IN HERTZ60.0 ALL LOCATIONS
PKWTUNPACKAGED UNIT WEIGHT0.312 POUNDS
THSDTHREAD SERIES DESIGNATORUNC
TTQYTERMINAL TYPE AND QUANTITY4 CLIP

Semiconductor's Certifications and Memberships
The only independent
distributor with a
NO CHINA SOURCING Pledge
  • All Orders are fulfilled in the U.S.A.
  • All shipments must comply with U.S.A export laws.
  • No exceptions.

“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”.

Thank You for Visiting.

We Hope that You Will Visit Us Again the Next Time You Need NSN Parts and Make Us Your Strategic Purchasing Partner.

Request for Quote

We use cookies to ensure that we give you the best experience on our website. If you continue to use this site we will assume that you are happy with it.