Mfg Part Number: ETN-1006 | Alternate P/N: ETN1006 | NSN : 5925-01-145-7746 |
NIIN : 011457746 | CAGE Code : 30086 | Manufacturer: Spd Electrical Systems Inc |
Item Name : Circuit Breaker | FSC : 5925 Circuit Breakers |
Thank you for your interest in the Circuit Breaker components we have available on After Market Industrials. This particular Spd Electrical Systems Inc item is listed alongside the NSN 5925-01-145-7746 and part number ETN-1006 for your reference. With current availability for this product, we encourage you to utilize our Instant RFQ service in order to receive a competitive quote within 15 minutes or less of you submitting a Request For Quote form. At After Market Industrials, we are backed by our rapid lead times and cost savings, allowing all of our customers to meet their operational deadlines. More than that, we thoroughly vet our products prior to shipping.
Take time in looking through our expansive catalogs and you will find that the NSN 5925-01-145-7746 can be found listed under CAGE Code 30086. We also have numerous other NSN parts, all of which are sourced from leading global manufacturers like Spd Electrical Systems Inc. To begin the purchasing process, fill out and submit a quote request that includes all of your part requirements and see why customers continually rely on us as their go-to sourcing solution. For additional questions, call or email us directly; we are on standby for our customers.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-145-7746 Item Description: Circuit Breaker | 5925 | 011457746 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
7 | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Etn-1006 | 5 | 1 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
ADAQ | BODY LENGTH | 5.875 INCHES NOMINAL |
ADAT | BODY WIDTH | 3.344 INCHES NOMINAL |
ADTV | CASE MATERIAL | PLASTIC |
AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 1.125 INCHES NOMINAL |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.228 INCHES NOMINAL |
AKPX | POLE QUANTITY | 3 |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 35.0 AMPERES AC ALL LOCATIONS AND 35.0 AMPERES DC ALL LOCATIONS |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 500.0 AC ALL LOCATIONS AND 250.0 DC ALL LOCATIONS |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 5000.0 AC ALL LOCATIONS AND 2500.0 DC ALL LOCATIONS |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
CPRJ | TRIP RELEASE METHOD | THERMAL ALL LOCATIONS |
CPRL | TRIP RELEASE CHARACTERISTIC | INSTANTANEOUS ALL LOCATIONS AND TIME DELAY ALL LOCATIONS |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 115.0 ALL LOCATIONS |
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | RELAY TRIP ALL LOCATIONS |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 10.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 200.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
CRCF | TRIP RELEASE AMBIENT TEMP RATING | 50.0 DEG CELSIUS NOMINAL ALL LOCATIONS |
CRTL | CRITICALITY CODE JUSTIFICATION | ZZZY |
FREQ | FREQUENCY IN HERTZ | 60.0 ALL LOCATIONS |
TTQY | TERMINAL TYPE AND QUANTITY | 6 PIN |
ZZZY | REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICS | MATERIAL WILL BE IN ACCORDANCE WITH SHIPS PARTS CONTROL CENTER ACTIVITY HX QUALITY CONTROL,MANUFACTURING AND TESTING SPECIFICATIONS |
![]() |