Mfg Part Number: CV9-1-30-60 | Alternate P/N: CV913060 | NSN : 4120-00-935-1612 |
NIIN : 009351612 | CAGE Code : 06534 | Manufacturer: Therm Air Mfg Co Inc |
Item Name : Air Conditioner | FSC : 4120 Air Conditioning Equipment |
Thank you for your interest in the Air Conditioner components we have available on After Market Industrials. This particular Therm Air Mfg Co Inc item is listed alongside the NSN 4120-00-935-1612 and part number CV9-1-30-60 for your reference. With current availability for this product, we encourage you to utilize our Instant RFQ service in order to receive a competitive quote within 15 minutes or less of you submitting a Request For Quote form. At After Market Industrials, we are backed by our rapid lead times and cost savings, allowing all of our customers to meet their operational deadlines. More than that, we thoroughly vet our products prior to shipping.
Take time in looking through our expansive catalogs and you will find that the NSN 4120-00-935-1612 can be found listed under CAGE Code 06534. We also have numerous other NSN parts, all of which are sourced from leading global manufacturers like Therm Air Mfg Co Inc. To begin the purchasing process, fill out and submit a quote request that includes all of your part requirements and see why customers continually rely on us as their go-to sourcing solution. For additional questions, call or email us directly; we are on standby for our customers.
MRC | Criteria | Characteristic |
---|---|---|
ZZZT | NONDEFINITIVE SPEC/STD DATA | 1 TYPE AND 2 CLASS |
SR-5 | DESIGN CONTROL REFERENCE | CV9-1-30-60 |
CYKM | HEATING CAPACITY IN BTU PER HOUR | 6000.0 NOMINAL |
FAAZ | PHASE | SINGLE |
ACZB | FREQUENCY RATING | 60.0 HERTZ NOMINAL |
CYGG | CABINET MATERIAL | ALUMINUM-COPPER FREE |
SFTT | SURFACE TREATMENT | ENAMEL |
AZAD | CONDENSER COOLING TYPE | AIR |
CYJE | COOLING CAPACITY IN BTU PER HOUR | 9000.0 NOMINAL |
FEAT | SPECIAL FEATURES | COOLING TOWER-NOT INCL.;EVAPORATOR CONDENSER-NOT INCL.;ACCESSORIES-NOT INCL.;1ST MOTOR-1.000 HP;SGL PKG,COMPACT VERTICAL UNIT |
SR-1 | NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | MIL-A-52767 |
AMSE | VOLTAGE RATING | 230.0 VOLTS NOMINAL |
SR-1 | SPEC/STD CONTROLLING DATA | |
ATJK | POWER SOURCE | ELECTRIC MOTOR |
SR-5 | MANUFACTURERS CODE | 06534 |
AZSD | COMPRESSOR UNIT TYPE | CLOSED |
AZSF | NOMINAL COOLING CAPACITY | 335.0 CUBIC FEET PER MINUTE |
AZSH | NOMINAL HEATING CAPACITY | 335.0 CUBIC FEET PER MINUTE |
SR-5 | THE MANUFACTURERS DATA | |
SR-1 | MANUFACTURERS CODE | 81349 |
ACDC | CURRENT TYPE | AC |
AAXX | MOUNTING TYPE | FLOOR OR WALL |
AWLX | ELECTRIC MOTOR QUANTITY | 2 |
ALCD | USAGE DESIGN | COMPRESSOR,FAN |
ARNA | COOLANT TYPE | FREON-22 |